Pre-Cut Natural PEEK Tubing

natural peek tubing

PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting, and is not affected by halide salts, high strength buffers, or other aggressive mobile phases that corrode stainless steel. The polymer surface will not leach metal ions into the eluent or extract metal-sensitive components from the sample. Note however that dichloromethane, THF, and DMSO may cause swelling in PEEK, and concentrated nitric and sulphuric acid will attack PEEK.

OD and ID tolerances for our PEEK tubing are ±.0005" for 360 micron and 1/32" tubing; ±.0005" for 1/16" tubing with ID up to .010" and ±.001" for IDs above .010"; and ±.003" for 1/8".

OD: 360 µm 1/32" 1/16" 1/8"
Pre-cut lengths: in feet in feet in feet in feet
  in meters in meters in meters in meters

360 µm OD PEEK tubing, in feet

Tubing ID Tolerance psi* Length Product No.
.002" ±.0005" 5200 10 feet TPK.102-10
25 feet TPK.102-25
100 feet TPK.102-100
.003" ±.0005" 5200 10 feet TPK.103-10
25 feet TPK.103-25
100 feet TPK.103-100
.004" ±.0005" 5200 10 feet TPK.104-10
25 feet TPK.104-25
100 feet TPK.104-100
.005" ±.0005" 5200 10 feet TPK.105-10
25 feet TPK.105-25
100 feet TPK.105-100
.006" ±.0005" 5200 10 feet TPK.106-10
25 feet TPK.106-25
100 feet TPK.106-100

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

1/32" OD PEEK tubing, in feet

Tubing ID Tolerance psi* Length Product No.
.0025" ±.0005" 5500 10 feet TPK.502-10
25 feet TPK.502-25
100 feet TPK.502-100
.005" ±.0005" 5500 10 feet TPK.505-10
25 feet TPK.505-25
100 feet TPK.505-100
.007" ±.0005" 5100 10 feet TPK.507-10
25 feet TPK.507-25
100 feet TPK.507-100
.010" ±.0005" 5100 10 feet TPK.510-10
25 feet TPK.510-25
100 feet TPK.510-100
.015" ±.0005" 4500 10 feet TPK.515-10
25 feet TPK.515-25
100 feet TPK.515-100

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

1/16" OD PEEK tubing, in feet

Tubing ID Tolerance psi* Length Product No.
.002" ±.0005" 6100 10 feet TPK102-10
25 feet TPK102-25
100 feet TPK102-100
.003" ±.0005" 6100 10 feet TPK103-10
25 feet TPK103-25
100 feet TPK103-100
.004" ±.0005" 6100 10 feet TPK104-10
25 feet TPK104-25
100 feet TPK104-100
.005" ±.0005" 6100 10 feet TPK105-10
25 feet TPK105-25
100 feet TPK105-100
.006" ±.0005" 6100 10 feet TPK106-10
25 feet TPK106-25
100 feet TPK106-100
.007" ±.0005" 5800 10 feet TPK107-10
25 feet TPK107-25
100 feet TPK107-100
.010" ±.0005" 5600 10 feet TPK110-10
25 feet TPK110-25
100 feet TPK110-100
.015" ±.001" 5000 10 feet TPK115-10
25 feet TPK115-25
100 feet TPK115-100
.020" ±.001" 4500 10 feet TPK120-10
25 feet TPK120-25
100 feet TPK120-100
.030" ±.001" 3500 10 feet TPK130-10
25 feet TPK130-25
100 feet TPK130-100
.040" ±.001" 2400 10 feet TPK140-10
25 feet TPK140-25
100 feet TPK140-100
.055" ±.001" 750 10 feet TPK155-10
25 feet TPK155-25
100 feet TPK155-100

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

1/8" OD PEEK tubing, in feet

Tubing ID Tolerance psi* Length Product No.
.060" ±.003" 3250 10 feet TPK260-10
25 feet TPK260-25
100 feet TPK260-100

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

360 µm OD PEEK tubing, in meters

Tubing ID Tolerance psi* Length Product No.
.002" ±.0005" 5200 5 m TPK.102-5M
10 m TPK.102-10M
25 m TPK.102-25M
.003" ±.0005" 5200 5 m TPK.103-5M
10 m TPK.103-10M
25 m TPK.103-25M
.004" ±.0005" 5200 5 m TPK.104-5M
10 m TPK.104-10M
25 m TPK.104-25M
.005" ±.0005" 5200 5 m TPK.105-5M
10 m TPK.105-10M
25 m TPK.106-25M
.006" ±.0005" 5200 5 m TPK.106-5M
10 m TPK.106-10M
25 m TPK.106-25M

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

1/32" OD PEEK tubing, in meters

Tubing ID Tolerance psi* Length Product No.
.0025" ±.0005" 5500 5 m TPK.502-5M
10 m TPK.502-10M
25 m TPK.502-25M
.005" ±.0005" 5500 5 m TPK.505-5M
10 m TPK.505-10M
25 m TPK.505-25M
.007" ±.0005" 5100 5 m TPK.507-5M
10 m TPK.507-10M
25 m TPK.507-25M
.010" ±.0005" 5100 5 m TPK.510-5M
10 m TPK.510-10M
25 m TPK.510-25M
.015" ±.0005" 4500 5 m TPK.515-5M
10 m TPK.515-10M
25 m TPK.515-25M

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

1/16" OD PEEK tubing, in meters

Tubing ID Tolerance psi* Length Product No.
.002" ±.0005" 6100 5 m TPK102-5M
10 m TPK102-10M
25 m TPK102-25M
.003" ±.0005" 6100 5 m TPK103-5M
10 m TPK103-10M
25 m TPK103-25M
.004" ±.0005" 6100 5 m TPK104-5M
10 m TPK104-10M
25 m TPK104-25M
.005" ±.0005" 6100 5 m TPK105-5M
10 m TPK105-10M
25 m TPK105-25M
.006" ±.0005" 6100 5 m TPK106-5M
10 m TPK106-10M
25 m TPK106-25M
.007" ±.0005" 5800 5 m TPK107-5M
10 m TPK107-10M
25 m TPK107-25M
.010" ±.0005" 5600 5 m TPK110-5M
10 m TPK110-10M
25 m TPK110-25M
.015" ±.001" 5000 5 m TPK115-5M
10 m TPK115-10M
25 m TPK115-25M
.020" ±.001" 4500 5 m TPK120-5M
10 m TPK120-10M
25 m TPK120-25M
.030" ±.001" 3500 5 m TPK130-5M
10 m TPK130-10M
25 m TPK130-25M
.040" ±.001" 2400 5 m TPK140-5M
10 m TPK140-10M
25 m TPK140-25M
.055" ±.001" 750 5 m TPK155-5M
10 m TPK155-10M
25 m TPK155-25M

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

1/8" OD PEEK tubing, in meters

Tubing ID Tolerance psi* Length Product No.
.060" ±.003" 3250 5 m TPK260-5M
10 m TPK260-10M
25 m TPK260-25

* Recommended maximum permanent working pressure (measured with ACN/Water 1:1 at room temperature)

CUSTOM PEEK TUBING

We now offer PEEK tubing custom- manufactured to meet your specific OD, ID, and color requirements. The OD range is .014" (360 micron) to 1/8", with a minimum ID of .002" for tubing up to 1/16" OD. (Maximum ID varies according to the OD.) Color coding can be solid or striped. For more information, contact us.

TRADEMARK

PEEK is a registered trademark of Victrex.