Applications –
Two position valves and injectors
(Non-Java)

Read more about Valco valves, Cheminert valves, or Diaphragm valves.



Applications

1. Alternate column regeneration - 10 port
2. Backflush of precolumn to vent - 6 port
3. Detector selection from two columns, or one column and auxiliary carrier
- 4 port

4. Dual microvolume sample injection - 6 port
5. Heart cut trapped in a loop and injected onto a second column - 10 port
6. Loop sampling with backflush of precolumn to vent - 10 port
7. Loop sampling with two column sequence reversal - 10 port
8a. Microvolume sample injection - 4 port (Valco and Cheminert valves)
8b. Microvolume sample injection - 4 port (Diaphragm valves)
9. Same sample to different loops - 8 port
10. Sample enrichment (cleanup) using dual precolumns - 10 port
11. Sample injection - 6 port
12. Sample injection and heart cut to detector - 10 port
13. Sample injection, end and heart cut to column 2, front cut to detector
- 10 port

14. Simultaneous injection of the same sample onto two separate columns
- 10 port

15. Simultaneous injection of the same sample onto three separate columns
- 14 port

16. Two column selection - 6 port
17. Two different samples to same column - 10 port
18. Two different samples to two columns - 12 port

top of page

4 ports

Detector selection from two columns, or one column and auxiliary carrier
Microvolume sample injection

6 ports

Backflush of precolumn to vent
Dual microvolume sample injection
Sample injection
Two column selection

8 ports

Same sample to different loops

10 ports

Alternate column regeneration
Heart cut trapped in a loop and injected onto a second column
Loop sampling with backflush of precolumn to vent
Loop sampling with two column sequence reversal
Sample enrichment (cleanup) using dual precolumns
Sample injection and heart cut to detector
Sample injection, end and heart cut to column 2, front cut to detector
Simultaneous injection of the same sample onto separate columns
Two different samples to same column

12 ports

Simultaneous injection of two different samples onto two different columns

14 ports

Simultaneous injection of the same sample onto three separate columns


Further reference

Multiposition valve applications