Gas purification
product heading



VICI heading




Gas Purifiers from VICI Mat/Sen

Gas specific purifiers
  • Original equipment in Agilent Mass Spec and LC Mass Spec
  • Point-of-use gas purification of helium, hydrogen, methane, nitrogen, carbon dioxide, or air
  • Reduce gas impurities from high PPM to low PPB levels
  • Decrease baseline noise and increase GC/MS sensitivity
  • Replace three traps with one gas purifier

Contact Mat/Sen
For ordering, product support, or more information about these products, email VICI Mat/Sen or call toll-free (877) 737-1887.


Jump to product numbers.

Gas purification is critical to GC performance. Several types of contaminants are detrimental - notably moisture, hydrocarbons, and oxygen. VICI Mat/Sen™ gas purifier modules are designed to be placed in-line with the GC carrier or detector gas supply to remove these contaminants from the analytical gases prior to entering the GC.

Mat/Sen gas purifiers dramatically reduce contaminant levels and absorb a greater variety of contaminants than other gas purification products. Advanced materials and design features guarantee that the modules will produce gases that are at least a factor of ten higher than a 99.9999% "chromatography grade" cylinder of gas when the purifier is supplied by a 99.995% cylinder. (illustration) The cost difference between the two grades of gas will pay for the cost of the gas purifier several times over during its operating life.

Gas purification is optimized by a multiple bed format. (illustration) Each bed functions at a lower contaminant concentration, resulting in a series of contaminant concentration gradients across the length of the gas purifier.

Safety note: Not to be used for purification of oxygen


Further reference

Fittings and gas purity
Printable data sheet
Carbon dioxide gas purifier
Nitrogen purifier for LC/MS
Nitrogen purifier for nitrogen generators
Purifier for CI/MS
Contaminant traps
Valco helium purifier (a heated purifier for maximum nitrogen removal)

to top

Product numbers

 Description   Product no.   
 With fittings for 1/8" tubing   
 Helium/inert   P100-1 * 
 Hydrogen   P200-1
 Nitrogen   P300-1
 Air   P400-1
 Methane   P500-1
 Carbon dioxide    P600-1
 With fittings for 1/4" tubing 
 Helium/inert   P100-2
 Hydrogen   P200-2
 Nitrogen   P300-2 **
 Air   P400-2
 Methane   P500-2
 Carbon dioxide    P600-2
*   Original equipment for Agilent Mass Spec and LC Mass Spec (Agilent part# 5182-3467)
**  Original equipment for Agilent Mass Spec and LC Mass Spec (Agilent part# G1946-80047)
 