| Fitting | Tubing OD | Bore | Product No. | |
| PEEK or electroformed nickel tubing | ||||
| Union | 1/32" | 100 µm | C-NEU.5XFPK | |
| 150 µm | C-NEU.5FPK | |||
| Fused silica tubing | ||||
| Union * | 125 - 175 µm |
100 µm |
C-NEU.5XFPK.15 | |
|
150 µm |
C-NEU.5FPK.15 | |||
| 175 - 225 µm |
100 µm |
C-NEU.5XFPK.20 | ||
|
150 µm |
C-NEU.5FPK.20 | |||
| 225 - 275 µm |
100 µm |
C-NEU.5XFPK.25 | ||
|
150 µm |
C-NEU.5FPK.25 | |||
| 275 - 325 µm |
100 µm |
C-NEU.5XFPK.30 | ||
|
150 µm |
C-NEU.5FPK.30 | |||
| 325 - 375 µm |
100 µm |
C-NEU.5XFPK.35 | ||
|
150 µm |
C-NEU.5FPK.35 | |||
* Includes required liners
Natural PEEK.
| Fitting | Tubing OD | Bore | Product No. | |
|
Reducing union |
1/32" to 1/16" |
200 µm | ZERU1.5FPK |
| Fitting | Bore | Product No. | |
| 1/32" OD tubing | |||
| Tee | 100 µm | C-NTXFPK | |
| 150 µm | C-NTFPK | ||
| Y | 100 µm | C-NYXFPK | |
| 150 µm | C-NYFPK | ||
| Cross | 100 µm | C-NXXFPK | |
| 150 µm | C-NXFPK | ||
| Fused silica tubing ** | |||
| Tee ** | 100 µm | C-NTXFPK | |
| 150 µm | C-NTFPK | ||
| Y ** | 100 µm | C-NYXFPK | |
| 150 µm | C-NYFPK | ||
| Cross ** | 100 µm | C-NXXFPK | |
| 150 µm | C-NXFPK | ||
** For each fused silica connection, a 27 mm liner is needed. Order separately.
| Description | Use with | Product No. | |
|
1/32" one-piece internal nut/ferrule |
Fittings and 6 port nanovolume valves (CN2-4346) |
C-NNFFPK | |
|
10 port nanovolume valves (CN2-4340) |
C-NNFLFPK | ||
|
1/32" external nut |
Unions and column end fittings |
C-EN.5FPKB | |
|
Ferrule |
External nut |
ZGF.5PK |
Use these liners with nanovolume connectors to adapt to the most common sizes of fused silica tubing. Natural PEEK. These do not include the embedded screen as in liners for column end fittings.
| Pkg/5: | Use with | FS tubing OD | Product No. | |
|
Liners, 27 mm long |
Internal nuts (nuts not included |
125 - 175 µm | C-NL.15L-5 | |
| 175 - 225 µm | C-NL.20L-5 | |||
| 225 - 275 µm | C-NL.25L-5 | |||
| 275 - 325 µm | C-NL.30L-5 | |||
| 325 - 375 µm | C-NL.35L-5 | |||
|
Liners, 10 mm long |
External nuts (nuts not included |
125 - 175 µm | C-NL.15S-5 | |
| 175 - 225 µm | C-NL.20S-5 | |||
| 225 - 275 µm | C-NL.25S-5 | |||
| 275 - 325 µm | C-NL.30S-5 | |||
| 325 - 375 µm | C-NL.35S-5 |